This document (DOC. NO.: YTY 0982, Revision 2) establishes the standard operating procedure for **Chlorine PPM Setting for On Line Chlorination Gloves** at YTY Industry (Manjung) Sdn Bhd. **Key components of the summary include:** * **Objective and Scope:** To define the chlorine formulation and dosing system requirements specifically for the production of online chlorinated medical examination gloves at the Manjung facility. * **Responsibility:** The Production Supervisor is responsible for setting and maintaining the correct chlorine dosing. * **Formulation and Calculation:** The document provides a mathematical formula for determining Parts Per Million (PPM) based on chlorine and water flow rates. It includes a **Chlorine Table** for quick reference, mapping chlorine dosing (from 0.5 to 10.0 kg/hr) to resulting PPM levels (from 80 to 1620 PPM). * **Quality Control:** Actual chlorine levels must be verified by laboratory tests every six hours. * **Maintenance Procedures:** Specific instructions are provided for "After Housekeeping" settings, including refreshing tank water and temporarily increasing the chlorine flow rate for 30 minutes prior to restarting the production line. The current revision (Rev 2) became effective on May 1, 2015.